Polk State College

Polk State College

Analysis of the existing chiller and boiler plant serving the Winter Haven campus. The study included the review of existing air-conditioning capacity vs. estimated needs to meet current code compliance, as well as additional capacity for planned future construction. A Life Cycle Cost Analysis compared four air-conditioning schemes: water cooled centrifugal chillers, air-cooled chillers, thermal […]

Read More
Jack R. Lamb Elementary School

Jack R. Lamb Elementary School

New construction school with a central energy plant with two air-cooled chillers and thermal storage, variable air volume chilled water air handlers, energy recovery ventilators, VAV boxes with electric reheat and Direct Digital Controls. Project included a Life Cycle Cost Analysis of multiple HVAC schemes over 25-year period. Electrical design included utility service to building […]

Read More
St. Joseph’s Hospital Central Energy Plant

St. Joseph’s Hospital Central Energy Plant

New 12 Megawatt 15kV power generation plant and campus distribution system. Entire campus back up by two natural gas and four diesel generators with stored fuel for 96 hours of run time. Separate campus medium voltage loops for essential and normal power systems. Major electrical upgrades and replacement of switchgear and feeders within most campus […]

Read More
James A. Haley VA Central Energy Plant

James A. Haley VA Central Energy Plant

New 14 megawatt 15kV power generation plan and underground campus distribution system.  Separate campus medium voltage distribution and pad mounted switches for essential and normal power systems. Major electrical upgrades to multiple buildings including the addition of 9 unit substations, 16 transfer switches, distribution and branch circuit panels. Campus wide SCADA system with monitoring and […]

Read More
BayCare Data Center

BayCare Data Center

Data center and office building to support 9 major hospitals in Tampa Bay area.  Facility designed with redundant utility and generator power sources for 2N (A+B) emergency; and critical power systems.  Project included MDF room, Network Operation Center, Computer Room, Staging, UPS room and support spaces.  Complete environmental and power monitoring system with graphical web […]

Read More
FCCI

FCCI

Three story, 230,000 square foot raised floor office building with a central atrium and two office wings. Full kitchen, dining room, outdoor dining terrace, fitness center and computer room. Two 720 ton cooling towers, chillers, multiple air handlers and a smoke evacuation system. Complete building management system including environmental, lighting and security. Two main switchgear […]

Read More
Port Tampa Bay

Port Tampa Bay

Refurbishment of three relocated gantry cranes for Port Tampa Bay.  Performance specification included the conversion of existing electrical bus bar pick-up system to a new pull-and-store horizontal cable reel power feed system.  New crane mounted GE 13.2kV – 4160/480V switchgear was specified along with general crane electrical upgrades and improvements.

Read More
Ring Power

Ring Power

32,000 SF office building for sales, service and parts support. MEP design for: Reception, lobby, open workstations and private offices. Specialized lighting and control systems designed for executive board room and theater. Variable air volume system throughout. Installed new fire alarm system, break rooms and ADA restrooms.

Read More
Verizon Central Energy Plant

Verizon Central Energy Plant

New Central Energy Plant with three diesel generators, four 1100 KVA UPS systems, three 600-ton variable speed chillers and 4000A double ended main switchgear. Permanent load bank system for testing generators and UPS systems. UPS power was delivered to the existing data center through four 1600 Amp switchboards configured in an A1/B1, A2/B2 configuration for […]

Read More
Port Tampa Bay

Port Tampa Bay

Three story, 42,000 square foot glass/steel structure featuring a 70 foot glass atrium with a 52 foot diameter world globe.  Design of emergency power, HVAC, plumbing and fire systems.  Two 150 ton air cooled chillers, central air handlers for each floor.  Central outside air and exhaust risers.  Direct digital control system, atrium air conditioning system […]